Inspection & Troubleshooting
| Service / device specification | Price / starting price | Charging unit | Normally included work | Possible exclusions | Conditions that may cause additional charges |
|---|---|---|---|---|---|
| Onsite electrical inspectionOnsite visit for a basic check and first advice. | RM100 | visit | Technician visit, basic visual check and initial advice. | Repair work, replacement parts and extended troubleshooting. | If repair, testing or materials are required after inspection. |
| Power trip / leakage inspectionTroubleshooting for power trips, leakage and basic fault isolation. | RM200 | inspection | Basic leakage or trip inspection, circuit isolation checks and safety advice. | Major rewiring, appliance repair, replacement parts and concealed fault repair. | If multiple circuits, hidden wiring faults or repeated testing are involved. |
Onsite electrical inspectionOnsite visit for a basic check and first advice.
Normally included work
Technician visit, basic visual check and initial advice.
Possible exclusions
Repair work, replacement parts and extended troubleshooting.
Conditions that may cause additional charges
If repair, testing or materials are required after inspection.
Power trip / leakage inspectionTroubleshooting for power trips, leakage and basic fault isolation.
Normally included work
Basic leakage or trip inspection, circuit isolation checks and safety advice.
Possible exclusions
Major rewiring, appliance repair, replacement parts and concealed fault repair.
Conditions that may cause additional charges
If multiple circuits, hidden wiring faults or repeated testing are involved.
Wiring
| Service / device specification | Price / starting price | Charging unit | Normally included work | Possible exclusions | Conditions that may cause additional charges |
|---|---|---|---|---|---|
| 2.5mm² wiringHigher-load wiring charged by confirmed meter length. | RM28 | meter | Cable pulling for the agreed route and standard connection preparation. | PVC casing, conduit, wall hacking, concealed work and special materials. | If the route is longer, access is difficult or ceiling or wall work is required. |
| 1.5mm² wiringLighting or basic point wiring charged by confirmed meter length. | RM23 | meter | Cable pulling for lighting or basic wiring points along the agreed route. | PVC casing, conduit, concealed wiring, wall hacking and special fittings. | If extra route length, difficult access or additional materials are required. |
2.5mm² wiringHigher-load wiring charged by confirmed meter length.
Normally included work
Cable pulling for the agreed route and standard connection preparation.
Possible exclusions
PVC casing, conduit, wall hacking, concealed work and special materials.
Conditions that may cause additional charges
If the route is longer, access is difficult or ceiling or wall work is required.
1.5mm² wiringLighting or basic point wiring charged by confirmed meter length.
Normally included work
Cable pulling for lighting or basic wiring points along the agreed route.
Possible exclusions
PVC casing, conduit, concealed wiring, wall hacking and special fittings.
Conditions that may cause additional charges
If extra route length, difficult access or additional materials are required.
Switches & Sockets
| Service / device specification | Price / starting price | Charging unit | Normally included work | Possible exclusions | Conditions that may cause additional charges |
|---|---|---|---|---|---|
| Replace or install heater switchStandard heater switch supply and installation. | RM80 | unit | Standard heater switch supply and installation for a suitable existing point. | New wiring run, DB modification, concealed work or non-standard switch model. | If new wiring, casing, hacking or extra materials are required. |
| Replace existing socketReplacement of one existing 13A plug socket at a suitable point. | RM80 | set | One standard SIRIM-approved 13A plug socket, replacement labour and basic operational testing. | New wiring, looping, a dedicated DB circuit, concealed work, wall repair and premium socket models are not included. | Damaged wiring, loose terminals, an unsuitable back box or fault diagnosis may add cost. |
| Add socket from existing circuitA new socket point extended from a suitable existing socket circuit.Looping is only available when the existing socket circuit, cable condition, circuit loading, earthing and protective devices are confirmed suitable after inspection. | From RM250 | set |
|
|
|
| New dedicated socket circuit from DBA separate quotation is required when the socket needs direct wiring from the DB box, an independent circuit or a new protective device. | Site assessment required | quotation | Site assessment of the DB box, intended load, wiring route and protective-device requirements. | Installation work and materials are not included until the separate quotation is approved. | Direct DB wiring, an independent circuit or a new protective device will be quoted after assessment. |
| Replace aircond switchReplacement of one existing aircond switch or isolator at a suitable point. | RM80 | set | One standard aircond double-pole switch or isolator, replacement labour and basic operational testing. | New wiring, MCB or RCCB / ELCB replacement, DB modification, aircond installation and premium models are not included. | Damaged wiring, unsuitable mounting, difficult access or other repairs require a separate quotation. |
| New aircond switch circuit from DBA new aircond switch wiring route from the DB box. This is not a looping package.This is not a looping package. The 2.5mm² cable package applies only when the aircond load, manufacturer requirements, wiring distance, installation method and existing electrical system are confirmed suitable. | From RM350 | set |
|
|
|
Replace or install heater switchStandard heater switch supply and installation.
Normally included work
Standard heater switch supply and installation for a suitable existing point.
Possible exclusions
New wiring run, DB modification, concealed work or non-standard switch model.
Conditions that may cause additional charges
If new wiring, casing, hacking or extra materials are required.
Replace existing socketReplacement of one existing 13A plug socket at a suitable point.
Normally included work
One standard SIRIM-approved 13A plug socket, replacement labour and basic operational testing.
Possible exclusions
New wiring, looping, a dedicated DB circuit, concealed work, wall repair and premium socket models are not included.
Conditions that may cause additional charges
Damaged wiring, loose terminals, an unsuitable back box or fault diagnosis may add cost.
Add socket from existing circuitA new socket point extended from a suitable existing socket circuit.
Looping is only available when the existing socket circuit, cable condition, circuit loading, earthing and protective devices are confirmed suitable after inspection.
Normally included work
- One standard SIRIM-approved 13A plug socket
- Looping from a suitable existing socket circuit
- Up to 5 metres of 2.5mm² x 3 surface wiring
- Standard PVC casing
- Standard back box and basic accessories
- Installation labour
- Basic operational testing
Possible exclusions
- New dedicated circuit from the DB box
- New or replacement MCB
- RCCB / ELCB replacement
- DB box modification
- Burnt or damaged wiring repair
- Concealed wiring
- Wall hacking
- Difficult access work
- Premium socket models
- Fault diagnosis
Conditions that may cause additional charges
- Additional wiring: RM28 / meter after the included 5 metres
New dedicated socket circuit from DBA separate quotation is required when the socket needs direct wiring from the DB box, an independent circuit or a new protective device.
Normally included work
Site assessment of the DB box, intended load, wiring route and protective-device requirements.
Possible exclusions
Installation work and materials are not included until the separate quotation is approved.
Conditions that may cause additional charges
Direct DB wiring, an independent circuit or a new protective device will be quoted after assessment.
Replace aircond switchReplacement of one existing aircond switch or isolator at a suitable point.
Normally included work
One standard aircond double-pole switch or isolator, replacement labour and basic operational testing.
Possible exclusions
New wiring, MCB or RCCB / ELCB replacement, DB modification, aircond installation and premium models are not included.
Conditions that may cause additional charges
Damaged wiring, unsuitable mounting, difficult access or other repairs require a separate quotation.
New aircond switch circuit from DBA new aircond switch wiring route from the DB box. This is not a looping package.
This is not a looping package. The 2.5mm² cable package applies only when the aircond load, manufacturer requirements, wiring distance, installation method and existing electrical system are confirmed suitable.
Normally included work
- One standard aircond double-pole switch or isolator
- Up to 5 metres of 2.5mm² x 3 surface wiring
- Standard PVC casing
- One suitable standard 1P MCB where applicable
- DB connection
- Installation labour
- Basic operational testing
Possible exclusions
- Aircond unit installation
- Aircond servicing
- Refrigerant work
- RCCB / ELCB replacement
- DB box modification
- Concealed wiring
- Wall hacking
- Difficult ceiling access
- Burnt or damaged wiring repair
- Premium switch or isolator
- Three-phase aircond supply
- Fault diagnosis
Conditions that may cause additional charges
- Additional wiring: RM28 / meter after the included 5 metres, where the same cable specification remains suitable
- Larger cable sizes or special protection requirements must be quoted separately.
- FastFix Electric provides electrical wiring, switch and isolator installation only. Aircond installation and servicing are not included.
Ceiling Fans
| Service / device specification | Price / starting price | Charging unit | Normally included work | Possible exclusions | Conditions that may cause additional charges |
|---|---|---|---|---|---|
| Replace or install ceiling fanStandard ceiling fan replacement or installation at a suitable existing point. | RM120 | unit | Removal of the existing fan where applicable, standard installation labour and basic operational testing. | Ceiling fan supply, new wiring, mounting-point modification, ceiling repair and remote-control accessories are not included. | High ceilings, difficult access, an unsafe mounting point, new wiring, regulator work or additional materials may add cost. |
Replace or install ceiling fanStandard ceiling fan replacement or installation at a suitable existing point.
Normally included work
Removal of the existing fan where applicable, standard installation labour and basic operational testing.
Possible exclusions
Ceiling fan supply, new wiring, mounting-point modification, ceiling repair and remote-control accessories are not included.
Conditions that may cause additional charges
High ceilings, difficult access, an unsafe mounting point, new wiring, regulator work or additional materials may add cost.
Circuit Protection Devices
| Service / device specification | Price / starting price | Charging unit | Normally included work | Possible exclusions | Conditions that may cause additional charges |
|---|---|---|---|---|---|
| 1P MCB supply and replacementSingle-pole MCB replacement with basic operational testing. | From RM50 | unit | Standard SIRIM-approved protective device, standard replacement labour and basic operational testing. | Premium brands, special protection types, DB repair, wiring repair and replacement of damaged accessories are not included in the standard price. | Burnt wiring, damaged terminals, DB box limitations, wiring faults or special protection types may add cost. |
| 32A 3P MCB supply and replacement32A three-pole MCB replacement after checking the DB condition. | From RM200 | unit | Standard SIRIM-approved protective device, standard replacement labour and basic operational testing. | Premium brands, special protection types, DB repair, wiring repair and replacement of damaged accessories are not included in the standard price. | Burnt wiring, damaged terminals, DB box limitations, wiring faults or special protection types may add cost. |
| 32A 2P RCCB / ELCB supply and replacementRCCB / ELCB replacement with final specification confirmed onsite.Final rating and leakage sensitivity must be confirmed after checking the existing installation. | From RM220 | unit | Standard SIRIM-approved protective device, standard replacement labour and basic operational testing. | Premium brands, special protection types, DB repair, wiring repair and replacement of damaged accessories are not included in the standard price. | Burnt wiring, damaged terminals, DB box limitations, wiring faults or special protection types may add cost. |
| 63A 4P RCCB / ELCB supply and replacementFour-pole RCCB / ELCB replacement for suitable three-phase installations.Final rating and leakage sensitivity must be confirmed after checking the existing installation. | From RM400 | unit | Standard SIRIM-approved protective device, standard replacement labour and basic operational testing. | Premium brands, special protection types, DB repair, wiring repair and replacement of damaged accessories are not included in the standard price. | Burnt wiring, damaged terminals, DB box limitations, wiring faults or special protection types may add cost. |
| Single-phase SPD surge protection packageSingle-phase SPD surge protection package with standard materials and installation.This package applies to a suitable single-phase supply. Final SPD type and suitability must be confirmed after checking the existing DB and earthing. | RM500 | package | Standard single-phase SPD materials, installation labour, DB connection and basic operational testing. | DB box modification, MCB or RCCB / ELCB replacement, burnt wiring repair, earthing repair and premium or special SPD models are not included. | Insufficient DB space, unsuitable earthing, damaged wiring or terminals, a supply-phase mismatch or extra wiring may add cost. |
| Three-phase SPD surge protection packageThree-phase SPD surge protection package with standard materials and installation.This package applies to a suitable three-phase supply. Final SPD type and suitability must be confirmed after checking the existing DB and earthing. | RM700 | package | Standard three-phase SPD materials, installation labour, DB connection and basic operational testing. | DB box modification, MCB or RCCB / ELCB replacement, burnt wiring repair, earthing repair and premium or special SPD models are not included. | Insufficient DB space, unsuitable earthing, damaged wiring or terminals, a supply-phase mismatch or extra wiring may add cost. |
1P MCB supply and replacementSingle-pole MCB replacement with basic operational testing.
Normally included work
Standard SIRIM-approved protective device, standard replacement labour and basic operational testing.
Possible exclusions
Premium brands, special protection types, DB repair, wiring repair and replacement of damaged accessories are not included in the standard price.
Conditions that may cause additional charges
Burnt wiring, damaged terminals, DB box limitations, wiring faults or special protection types may add cost.
32A 3P MCB supply and replacement32A three-pole MCB replacement after checking the DB condition.
Normally included work
Standard SIRIM-approved protective device, standard replacement labour and basic operational testing.
Possible exclusions
Premium brands, special protection types, DB repair, wiring repair and replacement of damaged accessories are not included in the standard price.
Conditions that may cause additional charges
Burnt wiring, damaged terminals, DB box limitations, wiring faults or special protection types may add cost.
32A 2P RCCB / ELCB supply and replacementRCCB / ELCB replacement with final specification confirmed onsite.
Final rating and leakage sensitivity must be confirmed after checking the existing installation.
Normally included work
Standard SIRIM-approved protective device, standard replacement labour and basic operational testing.
Possible exclusions
Premium brands, special protection types, DB repair, wiring repair and replacement of damaged accessories are not included in the standard price.
Conditions that may cause additional charges
Burnt wiring, damaged terminals, DB box limitations, wiring faults or special protection types may add cost.
63A 4P RCCB / ELCB supply and replacementFour-pole RCCB / ELCB replacement for suitable three-phase installations.
Final rating and leakage sensitivity must be confirmed after checking the existing installation.
Normally included work
Standard SIRIM-approved protective device, standard replacement labour and basic operational testing.
Possible exclusions
Premium brands, special protection types, DB repair, wiring repair and replacement of damaged accessories are not included in the standard price.
Conditions that may cause additional charges
Burnt wiring, damaged terminals, DB box limitations, wiring faults or special protection types may add cost.
Single-phase SPD surge protection packageSingle-phase SPD surge protection package with standard materials and installation.
This package applies to a suitable single-phase supply. Final SPD type and suitability must be confirmed after checking the existing DB and earthing.
Normally included work
Standard single-phase SPD materials, installation labour, DB connection and basic operational testing.
Possible exclusions
DB box modification, MCB or RCCB / ELCB replacement, burnt wiring repair, earthing repair and premium or special SPD models are not included.
Conditions that may cause additional charges
Insufficient DB space, unsuitable earthing, damaged wiring or terminals, a supply-phase mismatch or extra wiring may add cost.
Three-phase SPD surge protection packageThree-phase SPD surge protection package with standard materials and installation.
This package applies to a suitable three-phase supply. Final SPD type and suitability must be confirmed after checking the existing DB and earthing.
Normally included work
Standard three-phase SPD materials, installation labour, DB connection and basic operational testing.
Possible exclusions
DB box modification, MCB or RCCB / ELCB replacement, burnt wiring repair, earthing repair and premium or special SPD models are not included.
Conditions that may cause additional charges
Insufficient DB space, unsuitable earthing, damaged wiring or terminals, a supply-phase mismatch or extra wiring may add cost.
MCB and RCCB / ELCB replacement prices include a standard SIRIM-approved protective device, replacement labour and basic operational testing. The SPD package includes standard materials and installation.
Final pricing depends on brand, current rating, leakage sensitivity, DB box condition and existing wiring.
The correct device must be confirmed after checking the existing installation. Customers should not select their own rating or leakage sensitivity.
View SPD package detailsAdditional charges may apply for:- Burnt wiring or terminals
- Busbar replacement
- Neutral link or earth bar repair
- DB box modification
- Additional wiring
- Insufficient DIN rail space
- Fault diagnosis
- Three-phase wiring problems
- Premium brands or special protection types
Real electrical work
Circuit protection and DB inspection in the field.
These real FastFix work photos show the types of distribution boards we may encounter. The correct device and final scope are confirmed after inspecting the existing installation.


Additional charges
Extra work is explained before it proceeds.
Additional charges may apply when the work is outside the standard service scope or site condition requires more materials or labour.
Any additional work and pricing will be explained before work proceeds.- Additional wiring length
- PVC casing or conduit
- Concealed wiring
- Wall hacking
- Difficult ceiling access
- Additional materials
- DB box modification
- Outstation transport
- Work outside the standard scope
Need a confirmed quotation?